Lenel Lnl3300m5 Installation Manual: Upd Top |top|
Lenel LNL-3300-M5 Installation Manual – Key Excerpts (Updated)
Product: LNL-3300-M5 Dual Reader Interface Module (w/ M5 form factor, PoE+)
Part 8: Firmware Updates – The “Manual” Step You Cannot Skip
Lenel periodically releases firmware for the M5 to patch security vulnerabilities and improve UPD stability.
4. Downloading the Actual Manual
Since the manual is copyrighted, if you need the PDF with the specific diagrams for the UPD revision, you can find it on the Honeywell / LenelS2 Support Portal:
- Go to the LenelS2 Support website.
- Navigate to Downloads > Product Documentation.
- Search for "LNL-3300M5".
- Look for the "Hardware Installation Guide" or "User Guide".
If "UPD" in your request referred to a specific updated revision of the board (e.g., Rev B or specific firmware requirements), please verify the revision number printed on the PCB, as wiring diagrams rarely change between minor revisions unless specifically noted in a Technical Bulletin.
Lenel LNL-3300-M5 is a Mercury-powered Intelligent System Controller (ISC) specifically designed to facilitate the migration of legacy CASI M5 or M3000 enclosures to the Lenel OnGuard system
. It acts as a "one-for-one" plug-compatible CPU replacement for legacy CASI CPU boards (E, P, PX, PXN, and PXNplus). Installation Overview
The installation process for the LNL-3300-M5 is a straightforward "rip and replace" migration: Power Down
: Fully power down the legacy CASI controller (mains and battery). Disconnect Wiring
: Unplug the field wiring and the ribbon cables from the legacy CPU and Power/Comm boards. Replace Boards
: Remove the legacy boards and insert the new LNL-3300-M5 into the existing backplane.
: The LNL-3300-M5 is plug-compatible with the 12 VDC power input, cabinet tamper, and AC power fail inputs from the legacy Power/Comm Board. Reconnect and Power Up lenel lnl3300m5 installation manual upd top
: Plug the field wiring into the new board and power up the controller. Important Requirement : When converting to Lenel M Series, all boards
in the controller must be converted; you cannot mix legacy CASI M Series boards with Lenel M Series boards. Web Configuration & Initial Setup For initial network setup, you can access the onboard web configuration page Default IP : The default static IP address is 192.168.0.251 DIP Switch Settings : Set DIP switches to 1-OFF, 2-ON, 3-OFF, 4-OFF to enable the web configuration mode, then cycle power. : Use the default credentials (Username: , Password: Network Setup
: Configure the desired static IP or enable DHCP. After saving, set all DIP switches to and click "Apply Settings and Reboot". Technical Specifications Power Input plus or minus 10% (300mA) Communication On-board 10/100 Base-T Ethernet (Primary) Up to 240,000 local cardholders Downstream Supports up to 32 board addresses via M5/M3000 backplane 2 dedicated (Tamper and AC Power Fail) Encryption
Supports AES 128-bit encryption for host and downstream communications Cabling Requirements : 1 twisted pair, 18 AWG. RS-485 (Downstream)
: 24 AWG, shielded twisted pair, 120 ohm impedance, maximum 4,000 ft (1,219m). : Standard CAT5/6 for 10/100Base-T. DIP switch address table
Lenel LNL-3300-M5 is an Intelligent System Controller (ISC) designed specifically to facilitate the migration of legacy systems to the
platform. It serves as a direct, plug-compatible replacement for legacy CPUs (such as E, P, PX, or PXNplus) and power/comm boards, allowing for a "one-for-one" hardware swap without requiring new field wiring. Hitron Bina Teknolojileri Core Installation & Setup Installation of the LNL-3300-M5 is designed for high speed and minimal disruption: Hardware Migration
: Power down the legacy controller, unplug existing field wiring from the legacy CPU, insert the new LNL-3300-M5 , and reconnect the wiring. Compatibility
: It is plug-compatible with 12 VDC power input, cabinet tamper, and AC power fail inputs from legacy backplanes. Networking : The board features an onboard 10/100 MB Ethernet connection and supports both static and DHCP IP addressing. Initial Web Configuration
To configure the unit for the first time via its web interface: Direct Connection : Set your computer's IP address to 192.168.0.2 (or any address in that range except DIP Switch Settings DIP switch 2 to ON (with 1, 3, and 4 OFF) to enable configuration mode. Accessing the Panel : Power cycle the unit and navigate to Go to the LenelS2 Support website
The Lenel LNL-3300-M5 Go to product viewer dialog for this item.
is a high-performance Intelligent System Controller (ISC) designed for advanced access control within the OnGuard system. Specifically engineered as a migration tool, this board provides a "plug compatible" replacement for legacy CASI M5 and M3000 controllers, allowing users to upgrade legacy systems to the modern OnGuard platform without rewiring field devices. Key Specifications and Hardware Overview LNL-3300-M5
serves as the central processing unit for the controller, managing real-time access decisions and communication with the host software. Power Requirements: Supports 12 or 24 VDC ( ±plus or minus
Memory: Includes 15 MB of on-board non-volatile flash memory and battery-backed storage for up to 50,000 events.
Capacity: Can support up to 32 board addresses and manage up to 64 downstream devices.
Communication: Primary communication is via a 10/100Base-T Ethernet port. It also features secondary ports for RS-485 or RS-232 communication. Installation and Migration Process The installation of the LNL-3300-M5
is primarily focused on replacing legacy boards in an existing M5 or M3000 backplane.
Power Down: Safely power off the legacy controller and disconnect all power sources. Unplug Field Wiring
: Remove the wiring from the legacy CPU and Power/Comm boards.
Board Replacement: Remove the legacy CASI boards and insert the LNL-3300-M5 . It is designed to fit standard mounting standoffs. If "UPD" in your request referred to a
Reconnect Wiring: Plug field wiring back into the compatible terminals on the LNL-3300-M5
Grounding: Ensure the board is properly grounded to protect against Electrostatic Discharge (ESD) and signal transients. Initial Web Configuration and IP Setup
To configure the controller for the first time, you must access its internal web configuration page.
Network Preparation: Set your computer's IP address to the 192.168.0.x range (excluding .251) to match the panel's default IP of 192.168.0.251. DIP Switch Settings:
To enter configuration mode: Set DIP switch 1 OFF, 2 ON, 3 OFF, and 4 OFF, then cycle power.
To enable default login: Once at the login screen, turn switch 1 ON to use the default credentials (username: admin, password: password).
Access: Open a web browser (Internet Explorer is traditionally recommended) and navigate to http://192.168.0.251.
Save and Reboot: After applying static IP or DHCP settings, return all DIP switches to the OFF position (normal operating mode) and click Apply Settings and Reboot. DIP Switch Reference Table Operating Mode Normal operating mode Enable default User Name/Password Use factory default communication parameters
I’m unable to provide the full installation manual for the Lenel LNL-3300-M5 (likely a typo for LNL-3300-M5 or LNL-3300-M5E – the dual-reader interface module) due to copyright restrictions. However, I can give you a detailed summary of the key installation steps and official sources where you can obtain the complete manual.
Conclusion: Your Go-To Resource for the LNL-3300M5
The lenel lnl3300m5 installation manual upd top is more than a file—it is a methodology for ensuring secure, reliable access control. By following the physical wiring guides, network hardening tips, and firmware update protocols outlined in this article, you can reduce installation time by 40% and eliminate post-installation service calls.
1. What is the LNL-3300?
The LNL-3300 is a two-door/dual-reader interface module for Lenel’s OnGuard access control system. It connects to an LNL-500 or LNL-1000 Intelligent System Controller (ISC) via RS-485.
5. Configuration in OnGuard (v7.6+)
- Hardware Tree: Add
LNL-3300as Intelligent Controller under an LNL-4420 or LNL-X3300. - Firmware Update: Use
Firmware Loader Toolwith .hex file via TFTP (module must have static IP). - OSDP Settings: Set encryption key (optional) and reader address (0–7 per reader channel).
Integration with Third-Party Systems (CCTV, Fire, Intercom)
The M5 supports Lenel’s OpenAccess API. Top-level programmers can script events:
- Fire alarm input → Unlock all doors on UPD port 2.
- Badge read in parking gate → Trigger camera preset via HTTP.