(often searched as ) is a high-precision industrial weighing indicator and controller widely used for batching, filling, and check-weighing systems. Free versions of the manual are primarily available on document-sharing platforms and manufacturer repositories. Manual Availability & Download Sources
You can find the full user and calibration manuals through the following digital libraries: Scribd - XK3190-C8 User Manual
: Comprehensive 17-year-old archive containing technical parameters, interface data, and calibration steps. Archive.org - XK3190-C8 Instruction Manual
: A 12.6MB PDF version available for direct download, providing full implementation instructions. ManualLib - XK3190-C8 Weighing Indicator
: Lists manuals covering installation, interface data formats, and error code troubleshooting. Ningbo Maken Technology (Manufacturer Spec Sheet)
: Provides a quick-reference guide for technical specifications and main features. Key Technical Specifications
The indicator is designed for versatility in industrial environments with the following standard specs: Accuracy Class Conversion Speed : Up to 80 times per second using A/D technology. Load Cell Connection : Supports 1 to 8 load cells (350
) with a 6-wire system for automatic long-line compensation. Interface Options
: Standard RS232, RS422, or RS485 communication interfaces with baud rates from 600 to 9600. Control I/O
: Features 3 external digital inputs (for START/STOP/DISCHARGE) and 3 relay outputs. Operating Power : AC 110V~230V, 50/60Hz. Common Operational Features Operating Modes
: Configurable for one-component coarse-fine discharge, two-component feeding, or check-weigher modes. Calibration xk3190c801 manual free
: Includes 5-point non-linearity correction and the ability to replace an indicator by manually entering the previous unit's parameters without re-calibration. Display & Tips
Complete Guide to the XK3190-C8 Weighing Indicator The (often searched as C801) is a high-precision industrial weighing indicator widely used in batching scales, fixed-value control systems, and catch weighers. It utilizes advanced
A/D conversion technology to deliver fast and stable weight readings for critical industrial processes. Key Technical Specifications
Understanding the hardware capabilities is essential for proper integration into your control system. Accuracy Class: III, A/D Conversion: 24-bit technology with a conversion speed of 80 times/second. Load Cell Connectivity: Supports up to 8 load cells ( Input Signal Range: -19mVnegative 19 m cap V +19mVpositive 19 m cap V
Communication: Standard RS-232/422/485 interfaces with adjustable baud rates.
Relay Output: Includes 3 internal relay outputs for control automation. Calibration Procedure
To ensure accuracy, the indicator must be calibrated using a known standard weight.
Preparation: Ensure the scale is on a flat surface and the platform is empty.
Access Calibration: Turn the calibration switch on the back of the indicator to the "Allowable" position. Zero Point Calibration: The display will typically show [nLoAd].
Ensure no weight is on the scale and wait for the stable indicator light. (often searched as ) is a high-precision industrial
Press the [Input] (or [ACCU]) button to confirm the zero point. Load Calibration: The display will show [ALoAd].
Place a standard weight on the platform (recommended weight >10% of full capacity).
Input the weight value using the keypad and press [Input] to confirm.
Completion: Once the weight is correctly displayed, turn the calibration switch back to the "Forbidden" mode to save settings. Troubleshooting and Maintenance
Common errors can often be resolved without professional servicing.
Unstable Readings: Check the load cell connections and ensure the operating environment is free from strong vibrations or electromagnetic interference.
Zero Key Unresponsive: This occurs if the current weight exceeds the pre-set zero range. You may need to adjust the zero range parameter ( ) in the function menu.
Battery Care: If using the battery-powered version, the built-in battery should be fully charged before the first use. Charge it at least once a month to prolong its lifespan. Environmental Protection : The
is not waterproof or explosion-proof. Keep it away from direct sunlight, serious dust, and moisture. Where to Find the Full Manual
While many snippets are available online, a full PDF manual is necessary for detailed wiring diagrams and advanced parameter settings. XK3190-C8 Weighing Indicator Manual | PDF - Scribd Preserving Your Free Manual Once you download the PDF:
Shanghai Yaohua XK3190-C801 is a specialized weighing transmitter and industrial controller designed for high-speed data transmission and integration with PLC systems. While it shares some DNA with the standard XK3190-C8 series, the C801 is distinct for its guide-rail mounting and compact, 35mm-thick design. Essential Technical Specifications
The C801 is more than a simple display; it acts as a "transmitter head" for industrial control systems. Communication
: Supports dual serial ports (RS232 and RS485) and is compatible with the ModBus-RTU protocol Analog Outputs : Offers fully isolated signals including
, 0-5V, or 0-10V, which are critical for connecting to analog PLCs. Calibration
: Features a "weight-free" calibration function, allowing you to input sensor parameters directly to calibrate without physically loading the scale.
: Rated at Level 3 accuracy with high-speed A/D conversion capable of up to 80 samples per second. Operations and Manual Content
A full manual typically covers the following sections, often shared across the C8/C8+ family: C8 User Manual PDF | Parameter (Computer Programming)
Preserving Your Free Manual
Once you download the PDF:
- Save it to the cloud (Google Drive, Dropbox, OneDrive).
- Print a physical copy and keep it inside the scale junction box or near the indicator.
- Do not rename the file – keep it as
XK3190-C801_Manual_V5.2.pdffor easy future searches.
Hardware Overview (Page 1-12 of the Manual)
Before touching buttons, you must identify the physical parts of the C801.
3.2 Electrical Connection
| Connection | Cable Type | Polarity / Pinout | Notes | |------------|-----------|-------------------|-------| | Power Input | IEC‑C13 (or proprietary 12 VDC barrel) | L‑N‑E (for AC) or +‑‑ (for DC) | Verify voltage range (e.g., 100‑240 VAC, 50/60 Hz). Use the supplied power adapter. | | Data Interface | Ethernet RJ‑45, USB‑C, or HDMI (depends on model) | Follow the diagram in the spec sheet | For networked operation, configure a static IP or DHCP. | | Optional Sensors | 4‑pin Molex or RJ‑45 | Consult the wiring diagram for each sensor | Ensure proper termination to prevent reflections on high‑speed lines. |
A. The Keyboard Layout (Critical keys)
The C801 has 6 keys. Here is what they actually do:
- 【On/Off】 : Hold 3 seconds to power down. Tap to return to weigh mode from menus.
- 【Zero】 : Sets the current weight to zero (must be stable, within 2% of max capacity).
- 【Tare】 : Subtracts the weight of a container. Press again to clear the tare.
- 【Print】 : Sends data to the serial port. In setup mode, this acts as "Enter/Save."
- 【F1】 : Function key. Usually for "Units" (kg/lb) or "Gross/Net" toggle.
- 【F2】 : Function key. Often used for "Accumulation" or "Vehicle No."
5. Operating Procedures
| Procedure | Steps | Tips |
|-----------|-------|------|
| Start Capture | 1. Power on the unit.
2. Launch the vendor UI or SDK example.
3. Click “Start” or send the start command via API. | Verify that the LED status indicator is green (ready). |
| Saving Data | Choose a storage path (local SSD, NFS share, or cloud). Set file format (e.g., RAW, JPEG, H.264). | For high‑speed acquisition, use a high‑throughput SSD (≥ 500 MB/s). |
| Live View | Use the UI’s “Live View” window or stream via RTSP (rtsp://<IP>/live). | Adjust the display scaling to avoid latency. |
| Remote Control | Send commands over TCP/IP (e.g., GET /status, POST /settings). | Use authentication tokens; keep firmware up‑to‑date to mitigate security risks. |
| Shutdown | Stop capture, close software, then power down via the UI or by flipping the power switch. | Avoid unplugging the unit while data is being written. |