In the dimly lit workshop of a reclusive inventor named Silas, a small black box pulsed with a soft, amber glow. It was the XY-CD60 Battery Controller, the brain of his latest solar array. Silas didn't see it as just plastic and circuitry; he saw it as a sentinel guarding his power reserves.
He held the "SET" button down, entering the realm of parameters. The screen flashed "UP," and he dialed in the upper voltage limit, a ceiling to prevent his precious batteries from overcharging. Then came "dn," the lower floor, a safety net to ensure they never bled out into the "OFF" void of a deep discharge.
One night, a storm rolled in, obscuring the sun and demanding every drop of stored energy. Silas watched the LCD. The symbol "OUT" glowed—the Discharge Mode (P-2) was active, feeding his lights while he worked. As the voltage dipped toward the "dn" limit, the relay clicked—a sharp, mechanical snap that echoed in the quiet room. The XY-CD60 had done its duty, cutting the load to save the battery’s life.
When the first rays of dawn hit the panels, the display shifted. "IN" began to flash. The module had detected the incoming current, reopening the gates to let the energy flow back in. Silas tapped the "UP" button to check the percentage—45% and climbing. He smiled, knowing that as long as the sentinel was on guard, his light would never truly fail. Essential XY-CD60 Settings:
Charging Mode (P-1): Prevents overcharging by cutting off the charger when the voltage reaches the "UP" limit.
Discharging Mode (P-2): Protects batteries from damage by disconnecting the load when voltage hits the "dn" floor.
Emergency Stop: A short press of the DOWN button manually toggles the relay, instantly cutting power if needed. XY-CD60 Solar Battery Charger Controller Module User Manual
Enter Settings Mode: Long press the SET button to enter the parameter setting interface.
Switch Parameters: Short press the SET button to cycle through the parameters you wish to change.
Adjust Values: Short press or long press the UP/DOWN buttons to increase or decrease the parameter values. xycd60 manual
Save and Exit: Long press the SET button for approximately 5 seconds to save your values and return to the main interface. Working Modes
Charging Control Mode (P-1): The relay turns on when the voltage is below the lower limit (dn) and turns off when the voltage reaches the upper limit (UP).
Discharging Control Mode (P-2): The relay turns on when the voltage is above the upper limit (UP) and turns off when it drops below the lower limit (dn). Additional Features
Charging Time Control (OP): You can set a specific duration for charging. If the voltage does not reach the upper limit within this time, the relay will automatically disconnect.
Turn-on Delay (dLE): Adds a delay (in seconds) between reaching the activation voltage and the relay actually closing.
Force Turn-on (on): Allows for manual activation of the relay for testing purposes.
The XY-CD60 is a dual-function battery controller module designed for DC 6V–60V systems. It acts as an automated switch to protect lead-acid or lithium batteries from overcharging and over-discharging by managing the connection between a power source (charger), the battery, and the load. Core Specifications Voltage Range: DC 6V to 60V.
Working Modes: Charging Control (P-1) and Discharging Control (P-2).
Protection Features: Overcharge protection, under-voltage protection, and voltage monitoring. In the dimly lit workshop of a reclusive
Display: LCD screen showing voltage, percentage (calculated as
), and status symbols like "IN" (charging) or "OUT" (discharging). Operating Modes
The module supports two primary configurations based on your setup: Charging Control (P-1):
Setup: Connect a charger to the input and a battery to the output.
Operation: The relay closes (starts charging) when battery voltage drops below the Lower Limit (dn). It opens (stops charging) when voltage exceeds the Upper Limit (UP). Discharging Control (P-2):
Setup: Connect a battery to the input and a load to the output.
Operation: The relay closes (powers the load) when battery voltage is above the Upper Limit (UP). It opens (cuts power) when voltage falls below the Lower Limit (dn) to prevent deep discharge. Setup and Programming
Follow these steps to configure the XY-CD60 module according to its manufacturer instructions from IC Station:
Mode Selection: Long-press the SET button to toggle between P-1 and P-2 modes. Basic Programming Flow (from rare XYCD60 timer manual):
Setting Limits: Short-press SET to cycle through parameters: UP: Upper limit voltage. dn: Lower limit voltage. OP: Turn-on time (optional delay).
Adjusting Values: Use the UP and DOWN buttons to increase or decrease values.
Error Handling: If "ERR" flashes, it indicates the lower limit (dn) is set higher than the upper limit (UP). Safety and Installation Notes
Battery Requirement: If no battery is detected at the output during charging mode, the screen will display "nbE" and 0.00V.
Load Constraints: Ensure the load connected to the output does not exceed the relay's rated capacity (typically 10A–30A depending on the specific sub-model variant).
Mounting: The unit should be kept in a dry, dust-free area away from direct sunlight for optimal performance. 24V lithium battery setup?
XY-CD60 Solar Battery Charge Controller Module - RoboFactory
| Parameter | Value | |-----------|-------| | Input voltage range | 6V – 60V DC | | Max current | 10A (continuous, may vary by version) | | Measurement accuracy | ~1% | | Display | 3-digit / 4-digit 0.28” LED | | Control relay | Built-in, up to 10A | | Operating temp | -10°C ~ +60°C |